Do you want to remove a summary of products?
Product card sections
Close
Catalog
New products
Selection of products
download catalog
0
en
english
deutsch
français
polski
Русский
Close
Cable trays, Cable ladders and Channels
Define selection criteria
Help
Load
1
Load per 1 meter
0
▼
kN
kg
kN
kg
Distance between points of support
0
m
Filling value
2
Cable 1
Cable 2
Cable 3
Cable 4
Cable 1
5
Diameter (mm)
mm
5
Quantity (pcs.)
szt.
Cable 2
5
Diameter (mm)
mm
5
Quantity (pcs.)
szt.
Cable 3
5
Diameter (mm)
mm
5
Quantity (pcs.)
szt.
Cable 4
5
Diameter (mm)
mm
5
Quantity (pcs.)
szt.
Filling reserve
3
3
0
%
Filling correction
4
3
17
%
Product groups
5
Cable trays
System of mesh trays
Self supporting trays
Heavy external system
Cable ladders
Long span cable ladders
Subfloor channels
SELECT PRODUCTS
Print PDF
Clear criteria
Brak produktów w zestawieniu
Load per 1 meter
Distance between points of support
Diameter
Quantity
Diameter
Quantity
Diameter
Quantity
Diameter
Quantity
Filling reserve
Filling correction
×
Load
Selecting the products according to the load value allows choosing the most appropriate elements of any specific cable route on the assumption of the appropriate cable load at the specific distance between the points of support.
Provide the load value and the distance between the points of support, or only one of those parameters.
Provide the load value and the distance between the points of support, or only one of those parameters. In the the absence of information on the load value the application shall take into account the maximum allowable load between the points of support of the product. In the absence of information on the points of support the application shall take into account the maximum allowable distance between the points of support of the product.
Provide the load value and the distance between the points of support, or only one of those parameters. In the the absence of information on the load value the application shall take into account the maximum allowable load between the points of support of the product. In the absence of information on the points of support the application shall take into account the maximum allowable distance between the points of support of the product.
Next
Close
Filling value
Selection of products according to the filling value allows choosing the most appropriate elements of any specific cable route in relation to the number and cross-section of the cables inside the cable tray. To select the products specify the types of cables, from one to four, then provide the number of cables and their diameter.
Back
Next
Close
Filling reserve
The filling reserve restricts the choice of products to these which leave the margin of vacant space in the cable tray equal to or greater than the set value of the reserve.
Example
If the filling reserve is set at 70%, products will be selected for which the filling according to the determined criteria will be no more than 30% (there will be 70% of vacant space left in the tray).
Back
Next
Close
Filling correction
The cross- section of cables in a cable tray or cable ladder shall be calculated as follows:
S = number of cables • ¼ Π • cable cross-section2 • (1 + Filling correction value)
Filling correction = min (0%)
Cable cross- section shall be considered as a square with a side equal to the cable’s diameter. The results of calculation are underestimated -they indicate that actually fewer cables can be fitted in the cable tray or cable ladder section.
Filling correction = max (27%)
Cable cross- section value shall be considered as the field of any specific cable. Free space between the cables will not be taken into account. The results of calculation are overestimated- they indicate that actually more cables can be fitted in the cable tray or cable ladder section.
Note
By default, the correction value has been set at 17%. It is recommended to use the correction value between 7% and 20% - apply the smaller value when the cable tray or cable ladder has been filled with cables of small cross-section, and the higher value, when the larger cross-section is applied. At selection of the correction value other factors should be taken into account, such as the quality of the installation work or susceptibility of cables to heating.
Back